The Gigahertz Solutions ME3840B is a low-frequency analyser for measuring alternating electric and magnetic fields. With a frequency range from 5 Hz to 100 kHz, it supports both general measurements and more detailed analysis of different frequency ranges.
Its integrated switchable filter module allows separate assessment of frequency ranges associated with railway power, mains electricity and higher-frequency harmonics. Electric field strength is displayed directly in V/m and magnetic flux density in nT.
A switchable field-strength-proportional audio signal also helps locate and compare field sources during measurements.
Key Product Features
- measures low-frequency AC electric and magnetic fields
- wide frequency range from 5 Hz to 100 kHz
- integrated switchable frequency filter module
- direct readings in V/m and nT
- enables differentiated analysis of frequency ranges
- switchable field-strength-proportional audio signal
- LCD display with 1 V/m and 1 nT resolution
- low-battery indicator
- automatic power-off
- battery-powered operation
Measuring Ranges and Frequency Filters
The ME3840B measures:
- electric field strength: 1–1999 V/m
- magnetic flux density, single-axis: 1–1999 nT
- frequency range: 5 Hz–100 kHz
Three switchable filters are available for further analysis:
- 16 Hz band-pass
- 50 Hz high-pass
- 2 kHz high-pass
These filters allow different frequency components to be assessed separately and help narrow down potential field sources.
Sensors and Measurement Method
The ME3840B has a sensor for low-frequency AC electric fields and a single-axis sensor for low-frequency AC magnetic fields.
Signal evaluation uses RMS measurement. The manufacturer specifies an accuracy of ±2% ±14 digits at 50/60 Hz.
Audio Analysis
The switchable audio signal changes in proportion to the measured field strength, allowing changes to be followed acoustically while locating field sources.
Power Supply
The meter operates with a 9 V alkaline block battery. Average operating time is approximately 24 to 36 hours depending on the selected operating mode.
A low-battery indicator and automatic power-off function are included.
Pack Contents
- Gigahertz Solutions ME3840B low-frequency analyser
- grounding cable
- 9 V alkaline battery
- detailed operating instructions with background information
Product Details
- Product type: low-frequency analyser
- Measurements: electric field strength and magnetic flux density
- Frequency range: 5 Hz–100 kHz
- Electric measuring range: 1–1999 V/m
- Magnetic measuring range: 1–1999 nT
- Display resolution: 1 V/m / 1 nT
- Frequency filters: 16 Hz band-pass, 50 Hz high-pass, 2 kHz high-pass
- Signal evaluation: RMS
- Audio analysis: yes
- Magnetic sensor: single-axis
- Power supply: 9 V alkaline battery
- Operating time: approx. 24–36 hours
- Low-battery indicator: yes
- Auto power-off: yes
- Product weight stated by manufacturer: approx. 0.40 kg
- Warranty: 2 years
Gigahertz Solutions GmbH
Im Kessel 2
90579 Langenzenn
info@gigahertz-solutions.de
| Features |
| Audioanalyse: Feldstärkeproportionales Tonsignal |
| high frequency (mobile communications): nein |
| battery life: 24 bis 36 Stunden |
| measuring range electrical alternating fields: 1 - 1999 V/m |
| measuring range magnetic flux density: 1 - 1999 nT |
| low frequency (domestic electricity): ja |
| Auto Power off: ja |
| sensor: E-Feldsensor für elektrische NF-Wechselfelder H-Feldsensor für magnetische NF-Wechselfelder |
| ALLGEMEINE DATEN |
| Weight: 0,4 kg |
| guarantee: 2 Jahre |
| Property | Value |
|---|---|
| Dimensions l x w x h | 180 × 74 × 32 mm |
| frequency range | 5 Hz–100 kHz |
| Frequenzfilter: | 16-Hz-Bandpass, 50-Hz-Hochpass, 2-kHz-Hochpass |
| power supply | 9-V-Blockbatterie, Alkalimangan |
| Display | LCD-Display, Auflösung 1 V/m bzw. 1 nT |
| measurement accuracy | ±2 % ±14 Digits bei 50/60 Hz |
| signal information | RMS |
| included in delivery | ME3840B Messgerät, Erdungskabel, 9-V-Alkalimanganbatterie, ausführliche Bedienungsanleitung |